名称 |
额定风量M³/H |
机组截面尺寸 |
功能段长度MM |
防爆等级 |
|||||||||||||
W |
H |
混合段 |
初、中效过滤段 |
中效过滤段 |
亚高效过滤段 |
表冷段 |
电加热段 |
电极加热段 |
高压喷微雾段 |
风机段 |
消声段 |
空段 |
均流段 |
出风段 |
|||
防爆风柜功能段选型 |
2000 |
650 |
720 |
500 |
600 |
500 |
350 |
650 |
200 |
500 |
1000 |
880 |
900 |
600 |
600 |
300 |
ExdibmbIIBT4Gb |
3000 |
750 |
850 |
500 |
600 |
500 |
350 |
650 |
200 |
500 |
1000 |
970 |
900 |
600 |
600 |
300 |
||
4000 |
1200 |
720 |
500 |
600 |
500 |
350 |
650 |
200 |
500 |
1000 |
1050 |
900 |
600 |
600 |
300 |
||
5000 |
1200 |
850 |
500 |
600 |
500 |
350 |
650 |
200 |
500 |
1200 |
1050 |
900 |
650 |
650 |
300 |
||
6000 |
1400 |
850 |
500 |
600 |
500 |
350 |
650 |
200 |
550 |
1200 |
800 |
900 |
650 |
650 |
300 |
||
7000 |
1400 |
1050 |
600 |
600 |
500 |
350 |
700 |
200 |
550 |
1200 |
800 |
900 |
650 |
650 |
400 |
||
8000 |
1400 |
1150 |
600 |
600 |
500 |
350 |
700 |
200 |
550 |
1200 |
1230 |
900 |
650 |
650 |
400 |
||
9000 |
1400 |
1250 |
600 |
600 |
500 |
350 |
700 |
200 |
550 |
1200 |
880 |
900 |
650 |
650 |
400 |
||
10000 |
1400 |
1250 |
600 |
600 |
500 |
350 |
700 |
200 |
550 |
1400 |
880 |
1200 |
650 |
650 |
400 |
||
12000 |
1400 |
1450 |
600 |
600 |
500 |
350 |
700 |
200 |
550 |
1400 |
960 |
1200 |
650 |
650 |
400 |
||
14000 |
1700 |
1450 |
600 |
600 |
500 |
350 |
700 |
200 |
550 |
1400 |
1050 |
1200 |
650 |
650 |
500 |
||
16000 |
1700 |
1450 |
650 |
600 |
500 |
350 |
700 |
200 |
550 |
1400 |
1050 |
1200 |
650 |
650 |
500 |
||
18000 |
2000 |
1800 |
650 |
600 |
500 |
350 |
750 |
200 |
550 |
1400 |
1140 |
1200 |
650 |
650 |
500 |
||
20000 |
2000 |
1800 |
750 |
600 |
500 |
350 |
750 |
200 |
600 |
1500 |
1140 |
1200 |
650 |
650 |
500 |
||
25000 |
2350 |
2100 |
750 |
600 |
500 |
350 |
750 |
200 |
600 |
1500 |
1250 |
1200 |
650 |
650 |
600 |
||
30000 |
2350 |
2100 |
800 |
600 |
500 |
350 |
750 |
200 |
750 |
1500 |
1380 |
1200 |
750 |
750 |
600 |
||
35000 |
2700 |
2200 |
800 |
600 |
500 |
350 |
750 |
200 |
750 |
1500 |
1530 |
1200 |
750 |
750 |
600 |
||
40000 |
2700 |
2500 |
950 |
600 |
500 |
350 |
800 |
250 |
900 |
1600 |
1570 |
1200 |
800 |
800 |
700 |
||
45000 |
2700 |
2500 |
950 |
600 |
500 |
350 |
800 |
250 |
900 |
1600 |
1730 |
1200 |
800 |
800 |
700 |
||
50000 |
3050 |
2800 |
950 |
600 |
500 |
350 |
800 |
250 |
900 |
1800 |
1730 |
1200 |
800 |
800 |
700 |
||
55000 |
3350 |
2800 |
1000 |
600 |
500 |
350 |
800 |
250 |
900 |
1800 |
1730 |
1200 |
800 |
800 |
800 |
||
60000 |
3350 |
2800 |
1000 |
600 |
500 |
350 |
900 |
250 |
900 |
1800 |
1910 |
1200 |
800 |
800 |
800 |
||
65000 |
4000 |
2800 |
1100 |
600 |
500 |
350 |
900 |
250 |
900 |
1800 |
1910 |
1200 |
800 |
800 |
900 |
||
70000 |
4000 |
2800 |
1100 |
600 |
500 |
350 |
900 |
250 |
1000 |
1800 |
1910 |
1200 |
800 |
800 |
900 |
||
80000 |
4600 |
2800 |
1200 |
600 |
500 |
350 |
900 |
250 |
1000 |
2000 |
2070 |
1200 |
800 |
800 |
1000 |
||
90000 |
4900 |
2800 |
1300 |
600 |
500 |
350 |
900 |
250 |
1000 |
2000 |
2070 |
1200 |
800 |
800 |
1000 |
||
100000 |
5550 |
2800 |
1300 |
600 |
500 |
350 |
900 |
250 |
1000 |
2000 |
1770 |
1200 |
800 |
800 |
1100 |
||
120000 |
5550 |
3450 |
1600 |
600 |
500 |
350 |
900 |
250 |
1000 |
2000 |
1950 |
1200 |
800 |
800 |
1200 |
产品介绍:
全新风机组进风段宜增加循环水湿膜、喷淋、水洗等功能段,夏季过自来水起预冷、除尘作用;冬季供地下水或热水起预热、除尘、加湿作用。喷涂室循环风机组进风段宜增加阻漆板、漆雾过滤器、喷淋、天燃气燃烧等功能段,消除供风系统中的油漆异味,起除漆、加湿、加热作用。
本系列产品执行标准如下:
GB3836.1-2010《爆炸性环境 第1部分:设备通用要求》
GB3836.2-2010《爆炸性环境 第2部分:由隔爆外壳“d”保护的设备》
GB3836.4-2010《爆炸性环境 第4部分:由本质安全型“i”保护的设备》
GB3836.9-2006《爆炸性气体环境用电气设备 第9部分:浇封型“m”》
GB3836.15-2000《爆炸性气体环境用电气设备 第15部分:危险场所电气安装(煤矿除外)》
适用范围:
1.本产品适用于石油化工、冶金、纺织、食品、生物工程、制药、仓库、航天航空工程等爆炸性环境中,有温度控制要求的场所;
2.1区、2区危险气体场所
3.IIA、IIB类T1-T4组爆炸性气体或蒸汽环境;
4.环境温度:-5℃~+43℃。